A Direct-On-Line (DOL) starter

Call for Price

A Direct-On-Line (DOL) starter is a type of motor starter that is used to start and stop motors by directly connecting them to the power supply. It is one of the simplest and most common methods of starting three-phase induction motors, particularly in applications where the motor load is relatively small or where speed control is not required.

Here’s how a DOL starter typically operates:

1. **Contactor**: The DOL starter consists of a magnetic contactor, which is essentially a large relay, capable of handling the high currents required by the motor. The contactor is controlled by a start button, which, when pressed, energizes the coil of the contactor.

2. **Overload Relay**: In addition to the contactor, a DOL starter usually includes an overload relay. The overload relay is connected in series with the motor and is designed to protect the motor from damage due to overcurrent conditions. If the motor draws excessive current for an extended period, indicating a fault or overload, the overload relay will trip and disconnect power to the motor.

3. **Start Button**: The start button is used to energize the contactor coil and start the motor. When the start button is pressed, it sends a signal to the contactor coil, causing the contactor to close and connect the motor to the power supply.

4. **Stop Button**: The stop button is used to de-energize the contactor coil and stop the motor. When the stop button is pressed, it interrupts the circuit to the contactor coil, causing the contactor to open and disconnect power to the motor.

DOL starters are commonly used in applications where the starting current of the motor is not a concern or where the motor load is relatively constant. They are straightforward, reliable, and cost-effective solutions for starting motors in a wide range of industrial and commercial applications, such as pumps, fans, conveyor belts, and compressors. However, they can cause high inrush currents during motor starting, which may lead to voltage dips in the electrical system and mechanical stress on the motor and driven equipment.

Description

A Direct-On-Line (DOL) starter is a type of motor starter that is used to start and stop motors by directly connecting them to the power supply. It is one of the simplest and most common methods of starting three-phase induction motors, particularly in applications where the motor load is relatively small or where speed control is not required.

Here’s how a DOL starter typically operates:

1. **Contactor**: The DOL starter consists of a magnetic contactor, which is essentially a large relay, capable of handling the high currents required by the motor. The contactor is controlled by a start button, which, when pressed, energizes the coil of the contactor.

2. **Overload Relay**: In addition to the contactor, a DOL starter usually includes an overload relay. The overload relay is connected in series with the motor and is designed to protect the motor from damage due to overcurrent conditions. If the motor draws excessive current for an extended period, indicating a fault or overload, the overload relay will trip and disconnect power to the motor.

3. **Start Button**: The start button is used to energize the contactor coil and start the motor. When the start button is pressed, it sends a signal to the contactor coil, causing the contactor to close and connect the motor to the power supply.

4. **Stop Button**: The stop button is used to de-energize the contactor coil and stop the motor. When the stop button is pressed, it interrupts the circuit to the contactor coil, causing the contactor to open and disconnect power to the motor.

DOL starters are commonly used in applications where the starting current of the motor is not a concern or where the motor load is relatively constant. They are straightforward, reliable, and cost-effective solutions for starting motors in a wide range of industrial and commercial applications, such as pumps, fans, conveyor belts, and compressors. However, they can cause high inrush currents during motor starting, which may lead to voltage dips in the electrical system and mechanical stress on the motor and driven equipment.